Incinerator Operating period Anticipated daily period 8 hours

October 13, 2021 0 Comments 2 tags

Operating period Anticipated daily period 8 hours Maximum operating period 12hours Chamber Should be refractory lined to the following standards, hearth and lower section of chamber walls. Hot face materials Super dusty firebricks Limiting continuous service limit 1500°c Thickness 100mm Thermal conductivity 1.3W/mk Insulation Calcium silicate Limiting continuous service limit 1000°c Thickness 25mm Thermal conductivity 0.095w/mk Chimney/stack Should be manufactured from refractory lined mild steel or high quality air cooled stainless steel. The chimney/stack should have a minimum height of 10 meters above ground level Ignition burners Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves, fan and motor Maximum rating :               at least 450kw/hour Burner:                                  arranged for on/off operation Maximum consumption :   at least 6litres per hour Average consumption :      at least 3litres/hour After burner Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves fan and motor. Maximum rating :     At least 450kw/hour Burner:                        arranged for on/off operation Maximum consumption:     at least 9 litres/hour Average consumption:         at least 4.5 litres /hour Flue gas treatment

Incinerator Testing Fire”

October 13, 2021 0 Comments 1 tag

Pet Cremation Picture,dog cremation, pets incinerator”

October 12, 2021 0 Comments 1 tag

The pet animal cremation picture above is dog cremation. The dog weight is 15-20 kgs per hour, after burning 1 hour the dog material is black colour, there’s some stay

Oil filter for oil tube”

October 12, 2021 0 Comments 1 tag

Nozzle for Gasoline burner”

October 11, 2021 0 Comments 1 tag

Burner Cotrol Box”

October 11, 2021 0 Comments 1 tag

Incinerator User Guider”

October 10, 2021 0 Comments 1 tag

Refractory constructions incinerator

October 10, 2021 0 Comments 4 tags

* Burning Rate                                                     (50-120kg/hour)* Minimum Operating Temperature                (850°ϲ(Primary combustion)* Maximum Operating Temperature               (1450°ϲ(Afterburner chamber)* Secondary Burning Capacity                         (Compulsory)* Density Insulation                                           (20mm high)* Refractory Casting                                          (Minimum 65mm)* Heavy duty refracting lining to withstand    (1500°ϲ)* Average burn out time: Maximum                (3.0 hours)* Fuel Type                                                          (Diesel)* Fuel Consumption in L/hr:                            (7.5 to 9)* Residence time in secondary chamber     (2 sec.)* Residue ash post 100kg                               (Max. 3.8kg)* Installation period                                            (Maximum 7days)Type : Refractory constructionsSteel Structure 400+ Silica board + Fire Brick andCastable betweenSize : Outside – W 740 x L 1112 x H 790 / Inside – W 400 x L 800 x H 560 (mm)Fire load of Combustion volume : 0.18 m3Fire table area : 0.32 m2Material : SS400 x 6.0T, Silica Board, Fire Brick (SK-36), Castable (HACT-160)Temperature : 700 ~ 900 ℃Residual gas combustion in secondary chambers : ≥ 2secInput door size : W 200 x H 200 (mm)Ash door size : W 300 x H 400 (mm)Type : Refractory constructionsSteel Structure 400+ Silica board + Fire Brick and Castable betweenSize : Outside – W 740 x L 1112 x H 745 / Inside – W 400 x L 800 x H 600 (mm)  Fire load of Combustion volume : 0.19 m3  Fire table area : 0.32 m2Material :  SS400 x 6.0T, Silica Board 50T, Fire Brick (SK-36), Castable (HACT-160) Temperature : 1000 ~ 1100 ℃ WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected][email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100

Incinerator House Building”

October 10, 2021 0 Comments 1 tag