clinical waste burner
Australian burning style exclusive 5 25kg/hour double room ( LPG) burner or equal approved. Burner casing to be light steel with 125mm refractory liner containing essential and second room, secure
Australian burning style exclusive 5 25kg/hour double room ( LPG) burner or equal approved. Burner casing to be light steel with 125mm refractory liner containing essential and second room, secure
Key Features: * All models with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *according to sequence * High fever, long life of incinerator. * Free or minimal installation
Medical Waste Incinerator Purpose For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement. -Waste from health care activities -Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents. -Pathological waste, human fragments, blood, fetus, all body fluids, human tissues. -Sculpts, needles, infusion sets, blades, glass -Pharmaceutical waste. -Chemical waste laboratory reagents, disinfectants -Expired drugs. -Low radiation radioactive element. Medical waste incinerator: – Ecological Requirement – No odor -No fume -Definitive treatment of waste Medical waste incinerator: – Manufacturing Standards -UL,CE, ASME, ISA EURO emission standard 1.Medical waste incinerator Construction – CS plate shells, FB reinforcement, cast refractory linings, Insulation and 14 gage aluminum jacket. Type of fuel – Oil fired (Diesel) Burning Capacity – 250kg/hr and moisture up to 80%. Duration -8-16/Continuous Average fuel consumption – Very little as much as possible Control Type – PLC based operation Operating Temperature – Primary chamber 800oc ± 50 – Secondary Chamber 1050oc ± 50 Size of incinerator – Not more than 15mx7.20m Chimney – Ø630x25meter height and 7mm thick CS. Combustion efficiency- 99%
Download Product PDF Format Catalogue: YD Medical Incinerator Catalogue 2013
Temperature display and program set up (TS Model).
Medical Waste Incinerator Items/Model TS100(PLC) Burn Rate Average 100 kg/hour Feed Capacity Average 200 kg/feed Control Mode PLC Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber
Operating period Anticipated daily period 8 hours Maximum operating period 12hours Chamber Should be refractory lined to the following standards, hearth and lower section of chamber walls. Hot face materials Super dusty firebricks Limiting continuous service limit 1500°c Thickness 100mm Thermal conductivity 1.3W/mk Insulation Calcium silicate Limiting continuous service limit 1000°c Thickness 25mm Thermal conductivity 0.095w/mk Chimney/stack Should be manufactured from refractory lined mild steel or high quality air cooled stainless steel. The chimney/stack should have a minimum height of 10 meters above ground level Ignition burners Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves, fan and motor Maximum rating : at least 450kw/hour Burner: arranged for on/off operation Maximum consumption : at least 6litres per hour Average consumption : at least 3litres/hour After burner Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves fan and motor. Maximum rating : At least 450kw/hour Burner: arranged for on/off operation Maximum consumption: at least 9 litres/hour Average consumption: at least 4.5 litres /hour Flue gas treatment
Containerized Incinerator with ISO Container|Mobile Incinerator|Whole Building Dispatch|Up to 100kgs per hour Capacity
Items/Model TS30(PLC) TS50(PLC) Burn Rate 30 kg/hour 50 kg/hour Feed Capacity 60kg 100kg Control Mode PLC PLC Combustion Chamber 330L 560L Internal Dimensions 75x75x60cm 100x80x70cm Secondary Chamber 180L 280L Smoke
Waste Incinerator Operation Room, inside with waste incinerator and if needed, there will be a waste storage room beside.