Design standard Multiple chamber incinerator

October 21, 2021 0 Comments 3 tags

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse  Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length  Width  Height  Extra width for burners

Incinerator Rated Capacity: 100/KG/Hr

October 20, 2021 0 Comments 3 tags

Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements  Primary Combustion Chamber  Waste Charging Door: Provided with refractory lining with sealing gaskets  Ash Removed Door: Provided with refractory lining with sealing gaskets  Outer Body MOC: Mild Steel, 5mm  Primary Chamber: Stainless Steel  Operating Temperature :800. ± 50◦C  Insulation: Insulation Brick  Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load )  Electrical Supply :3 Phase 440 Volt  Control Panel  MOC: Mild Steel Power Coated No. of Temp: Controllers : 2 Nos  Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase. I.D.Fan Type: Centrifugal Type  MOC: Mild Steel  Capacity:2 HP/3Phase  Make of Motor: Kirloskar /Havells/Crompton Combustion Air Fan Type: Centrifugal Type  Capacity: 1HP/3Phase  Make of Motor: Kirloskar /Havells/Crompton Stack: Type:  Wire Supported  MOC:  Mild Steel of ISstd Height :3 Meters or more

Pet Crematorium

October 20, 2021 0 Comments 16 tags

Basic Info. Export Markets:Global Additional Info. Trademark:clover Origin:Clover Product Description we would like to refresh or change incinerator with new one the incinerator contain 3 units each unit 400kg/h, if

Incinerator Rated Capacity: 100/KG/Hr

October 18, 2021 0 Comments 3 tags

Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements  Primary Combustion Chamber  Waste Charging Door: Provided with refractory lining with sealing gaskets  Ash Removed Door: Provided with refractory lining with sealing gaskets  Outer Body MOC: Mild Steel, 5mm  Primary Chamber: Stainless Steel  Operating Temperature :800. ± 50◦C  Insulation: Insulation Brick  Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load )  Electrical Supply :3 Phase 440 Volt  Control Panel  MOC: Mild Steel Power Coated No. of Temp: Controllers : 2 Nos  Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase. I.D.Fan Type: Centrifugal Type  MOC: Mild Steel  Capacity:2 HP/3Phase  Make of Motor: Kirloskar /Havells/Crompton Combustion Air Fan Type: Centrifugal Type  Capacity: 1HP/3Phase  Make of Motor: Kirloskar /Havells/Crompton Stack: Type:  Wire Supported  MOC:  Mild Steel of ISstd Height :3 Meters or more

a complete destruction of waste from various hospital services

October 17, 2021 0 Comments 3 tags

Medical Waste Incinerator Purpose For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement. -Waste from health care activities -Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents.  -Pathological waste, human fragments, blood, fetus, all body fluids, human tissues. -Sculpts, needles, infusion sets, blades, glass -Pharmaceutical waste.  -Chemical waste laboratory reagents, disinfectants -Expired drugs.  -Low radiation radioactive element. Medical waste incinerator: – Ecological Requirement – No odor -No fume -Definitive treatment of waste Medical waste incinerator: – Manufacturing Standards  -UL,CE, ASME, ISA EURO emission standard  1.Medical waste incinerator  Construction – CS plate shells, FB reinforcement, cast refractory linings,                          Insulation and 14 gage aluminum jacket.  Type of fuel – Oil fired (Diesel) Burning Capacity – 250kg/hr and moisture up to 80%. Duration -8-16/Continuous   Average fuel consumption – Very little as much as possible Control Type – PLC based operation Operating Temperature – Primary chamber 800oc ± 50                                      – Secondary Chamber 1050oc ± 50 Size of incinerator – Not more than 15mx7.20m Chimney – Ø630x25meter height  and 7mm thick CS. Combustion efficiency- 99%

a complete destruction of waste from various hospital services

October 16, 2021 0 Comments 3 tags

Medical Waste Incinerator Purpose For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement. -Waste from health care activities -Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents.  -Pathological waste, human fragments, blood, fetus, all body fluids, human tissues. -Sculpts, needles, infusion sets, blades, glass -Pharmaceutical waste.  -Chemical waste laboratory reagents, disinfectants -Expired drugs.  -Low radiation radioactive element. Medical waste incinerator: – Ecological Requirement – No odor -No fume -Definitive treatment of waste Medical waste incinerator: – Manufacturing Standards  -UL,CE, ASME, ISA EURO emission standard  1.Medical waste incinerator  Construction – CS plate shells, FB reinforcement, cast refractory linings,                          Insulation and 14 gage aluminum jacket.  Type of fuel – Oil fired (Diesel) Burning Capacity – 250kg/hr and moisture up to 80%. Duration -8-16/Continuous   Average fuel consumption – Very little as much as possible Control Type – PLC based operation Operating Temperature – Primary chamber 800oc ± 50                                      – Secondary Chamber 1050oc ± 50 Size of incinerator – Not more than 15mx7.20m Chimney – Ø630x25meter height  and 7mm thick CS. Combustion efficiency- 99%

Incinerator Crematory

October 15, 2021 0 Comments 16 tags

Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Origin:Nanjing Product Description Nanjing Clover Medical Technology Co., Ltd., local in Nanjing city, China.

FFP2 Breathing mask System

October 13, 2021 0 Comments 16 tags

平面口罩机参数: Semi-Automatic Mask Machine l Power supply: 3.3KW mono phase l Mask Size: 175mm*80-100mm (two or 3 layers) l Nonwoven (GMS): 10-50g l Ability: 120 into 150pcs/min l Dimension(L*W*H):3800mm*500mm*1400mm l Net Weight: about 1000kg   焊接机参数: Welding Machine l Ability:

Programme on Small Scale Medical Waste Incinerators for Primary Health Care Clinics in South Africa

October 11, 2021 0 Comments 16 tags

TABLE OF CONTENTS OBJECTIVE OF THE PROGRAMME 4 STRUCTURE OF THE PROGRAMME 4 COLLABORATORS INVOLVED IN THE PROGRAMME 4 STAKEHOLDERS INVOLVED IN THE PROGRAMME 4 LABORATORY TRIALS 5 FIELD TRIALS

Refractory constructions incinerator

October 10, 2021 0 Comments 4 tags

* Burning Rate                                                     (50-120kg/hour)* Minimum Operating Temperature                (850°ϲ(Primary combustion)* Maximum Operating Temperature               (1450°ϲ(Afterburner chamber)* Secondary Burning Capacity                         (Compulsory)* Density Insulation                                           (20mm high)* Refractory Casting                                          (Minimum 65mm)* Heavy duty refracting lining to withstand    (1500°ϲ)* Average burn out time: Maximum                (3.0 hours)* Fuel Type                                                          (Diesel)* Fuel Consumption in L/hr:                            (7.5 to 9)* Residence time in secondary chamber     (2 sec.)* Residue ash post 100kg                               (Max. 3.8kg)* Installation period                                            (Maximum 7days)Type : Refractory constructionsSteel Structure 400+ Silica board + Fire Brick andCastable betweenSize : Outside – W 740 x L 1112 x H 790 / Inside – W 400 x L 800 x H 560 (mm)Fire load of Combustion volume : 0.18 m3Fire table area : 0.32 m2Material : SS400 x 6.0T, Silica Board, Fire Brick (SK-36), Castable (HACT-160)Temperature : 700 ~ 900 ℃Residual gas combustion in secondary chambers : ≥ 2secInput door size : W 200 x H 200 (mm)Ash door size : W 300 x H 400 (mm)Type : Refractory constructionsSteel Structure 400+ Silica board + Fire Brick and Castable betweenSize : Outside – W 740 x L 1112 x H 745 / Inside – W 400 x L 800 x H 600 (mm)  Fire load of Combustion volume : 0.19 m3  Fire table area : 0.32 m2Material :  SS400 x 6.0T, Silica Board 50T, Fire Brick (SK-36), Castable (HACT-160) Temperature : 1000 ~ 1100 ℃ WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected][email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100