Pig corpses / stray dogs and larger animal carcasses

October 24, 2021 0 Comments 4 tags

Pig corpses / stray dogs and larger animal carcasses – Load capacity in the range of up to 300 kg / Burn rate approx. 50 kg per hour Temperature Controlled Burner. Incinerators to be designed to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, reliable, economical Incinerator with relevant control, easy to operate and self-contained. Units to be pre-assembled, pre-piped, pre-wired & tested before Transport / Export The supply will comprise the special equipment for effective medical / clinical waste management as mentioned above for a new private environment management company with operations in West and East Malaysia; Indonesia and Thailand to carry out those professional services in order to comply with the safe disposal requirements for clinical and medical waste in the region and to meet the higher technical standard in this particular field. 1.Burning rate: 250 Kg/hr.  2.It should be able to Operate not Less than 10 hours/day 3.This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…  4.Design Specification: Types A, B, C, D, and E of medical waste 5.“PYROLYTIC” combustion, by controlling the gasification of waste.  6.The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings. 7.It should be able to reduce the volume of wastes by 98%. 8.It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.  The incineration should be completely free from visible smoke as well as offensive odours.  9. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg  The Temperatures of combustion: Minimum will be 850oC and max 1400oC Post combustion: >1100oC. 10. The Internal diameter of the Chimney: Ø 400mm² and its height: 8 Meter   11. The Volume of the combustion chamber: Not Less Than 2.3 M³  12. Burner operation should be Automatic On/Off 13. Fuel : diesel, LPG, Natural Gas, Bio fuel 14. The supplier must provide  necessary information for the best of  the installation 

Dual Combustion Chamber Containerized Mobile Burner Family Pet Canine Dog&& & & Pet Cat Cremation Installation in Addition to also Assigning

October 24, 2021 0 Comments 1 tag

Double Combustion Chamber Containerized Mobile Incinerator All waste burner design with dual burning chamber. Heat, Smoke Remedy , No black smoke, Environment-friendly. Family Pet Dog&Cat Cremation The burner mounted in

Waste incineration market power is Extreme level of Proper centers to be boosted

October 23, 2021 0 Comments 1 tag

[China] Solid Waste Environmental online waste incineration fields growth momentum is difficult, as well as also the brightest of resources going after also appear various times in the in 2014

Waste Administration Preparation

October 23, 2021 0 Comments 1 tag

If burning and also incineration is utilized, the gadgets selected requirement to be made as well as sized to match the waste produced, lessen fire danger as well as likewise

Design standard Multiple chamber incinerator

October 23, 2021 0 Comments 3 tags

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse  Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length  Width  Height  Extra width for burners

MEDIUM-CAPACITY ANIMAL CARCASS INCINERATOR HICLOVER Model TS100( PLC).

October 22, 2021 0 Comments 1 tag

MEDIUM-CAPACITY ANIMAL CARCASS INCINERATOR HICLOVER Model TS100(PLC) with wet scrubber optional Items/Model TS100( PLC) Photo Principle Waste Incineration Treatment( Fowl as well as dead fish Chamber Volume 0.97 m3 ––

Clinical Waste Incinerators

October 22, 2021 0 Comments 1 tag

Nanjing Clover Medical Modern Technology Co., Ltd. is a leading waste burner manufacturer in China. We’re local supplier and also among the largest merchant of China.The manufacturing center workshop neighborhood

Design standard Multiple chamber incinerator

October 21, 2021 0 Comments 3 tags

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse  Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length  Width  Height  Extra width for burners

Disposal of biohazard waste

October 21, 2021 0 Comments 1 tag

Nanjing Clover Medical Innovation Co., Ltd. is a leading waste incinerator manufacturer in China. We’re local manufacturer and one of the largest merchant of China. Pyrolytic burner apparatus technological is

Containerized Mobile Incinerator

October 21, 2021 0 Comments 1 tag

Containerized Mobile Incinerators Main Feature: — Dual Combustion Chamber — Dual Italy Burner –Burning Rate: 10-100kgs per hour –Combustion Chamber: 0.1M3-1.2M3 — Mobile Incinerator, Standard shipping containers, Easy to move/transport