Medical Waste Incinerator YD Model is our traditional product for market. All series included burning capacity 10kgs per hour, 30kgs per hour,50kgs per hour,100kgs per hour,150kgs per hour,300kgs per hour,500kgs per hour. Up to now, all versions sale to all around the world and have good feedback from end-customer. The YD Model medical incinerator have multi-combustion chamber and basic dry scrubber (smoke filter chamber) with reasonable project budget. For the cleaner emission demand, we accept custom made wet scrubber for incinerator, which will be also our next working by focusing on emission technical.

 

Model YD-30
Burning Rate 30 kgs/hour
Feed Capacity 60 kgs
Paimary Combustion Chamber 360 Liters
Secondary Combustion Chamber 200 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.59Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 10.2–19.8 kg/hour
Gas Consumption (Natural Gas) 9.8–20 m3/hour
Internal Dimensions 100 x 60 x 60cm (paimary chamber)
External Dimensions 145 x 90 x 260cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 200 Liters
Door Opening 48 x 60cm
Chimney Length 5.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 2300 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800℃–1000℃
Secondary Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal

 

[ecwid widgets="productbrowser search categories" default_category_id="CATEGORY_ID" default_product_id="PRODUCT_ID" lang="EN"]

Explore More

Google快讯 – waste incinerator

waste incinerator 每天更新 ⋅ 2021年9月29日 新闻 Protesters attempt to blockade EfWs across England | MRW – Materials Recycling World Materials Recycling World XR said it opposed incinerators because they “emit

Incinerator Operating period Anticipated daily period 8 hours

Operating period Anticipated daily period 8 hours Maximum operating period 12hours Chamber Should be refractory lined to the following standards, hearth and lower section of chamber walls. Hot face materials Super dusty firebricks Limiting continuous service limit 1500°c Thickness 100mm Thermal conductivity 1.3W/mk Insulation Calcium silicate Limiting continuous service limit 1000°c Thickness 25mm Thermal conductivity 0.095w/mk Chimney/stack Should be manufactured from refractory lined mild steel or high quality air cooled stainless steel. The chimney/stack should have a minimum height of 10 meters above ground level Ignition burners Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves, fan and motor Maximum rating :               at least 450kw/hour Burner:                                  arranged for on/off operation Maximum consumption :   at least 6litres per hour Average consumption :      at least 3litres/hour After burner Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves fan and motor. Maximum rating :     At least 450kw/hour Burner:                        arranged for on/off operation Maximum consumption:     at least 9 litres/hour Average consumption:         at least 4.5 litres /hour Flue gas treatment

Google快讯 – medical waste

medical waste 实时更新 ⋅ 2021年9月14日 新闻 Medical waste dumped near Puttu Vikki bridge – The Hindu The Hindu However, when officials from TNPCB – Coimbatore South visited the spot in