Basic Info.

Model NO.:TS10 PLC
Pullution Sources:Solid Waste Processing
Processing Methods:Physics
Export Markets:Global

Additional Info.

Trademark:Clover
Packing:Wooden Carton
Standard:10 kg per hour
Origin:China
Production Capacity:1500units/Yesr

Product Description

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., clover medical limited Saudi, clover medical limited yd-20c, clover medical. Net, clover-incinerator, clover+incinerator, up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

Application Scope: 
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 
3. Community & Sea Port & Station: Municipal Solid Waste, etc. 
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation 
Nanjing Clover Medical Technology Co., Ltd. 
Tel: +86-25-84610201 
Fax: +86-25-84610406 
Nanjing City, China

Items/Model TS10(PLC)
Burn Rate 10 kg/hour
Feed Capacity 20kg
Control Mode PLC
Combustion Chamber 100L
Internal Dimensions 50x50x40cm
Secondary Chamber 50L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.5Kw
Oil Consumption (kg/hour) 5.4–12.6
Gas Consumption (m3/hour) 6.2–11.4
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 30x30cm
Chimney 3Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800degree–1000 degree
2nd. Chamber Temperature 1000degree-1200degree
Residency Time 2.0 Sec.
Gross Weight 1500kg
External Dimensions 140x90x120cm
 
[ecwid widgets="productbrowser search categories" default_category_id="CATEGORY_ID" default_product_id="PRODUCT_ID" lang="EN"]

Explore More

Capacidad máxima de residuos médicos del incinerador

Información básica. No. de modelo: fabricantes de incineradores de desechos médicos Mercados de exportación: Global Descripción del producto Nanjing Clover Medical Technology Co., Ltd. es un fabricante líder de incineradores

HICLOVER Incinerator What is incinerators used in hospitals?

Is medical waste an incinerator? What is Medical Waste Incineration? Medical waste incineration is the process of burning specific wastes, including pathological, trace chemotherapy and non-hazardous pharmaceutical wastes as it is considered the safest, most effective means of treatment and prevents harm to the environment and our health in general.   How medical waste is incinerated? The pyrolytic incinerator comprises a pyrolytic chamber and a post-combustion chamber. Medical waste is thermally decomposed in the pyrolytic chamber through an oxygen-deficient, medium-temperature combustion process (800– 900°C), producing solid ashes and gases. What is incinerators used in hospitals? Medical incinerators are designed safely to dispose of harmful materials at high temperatures. The process ensures no harmful gases are released  into the environment. Medical waste incinerators have scrubbers to clean the polluted gases and other particulate matter.   Can biomedical waste be incinerated? As stated by Health Care Without Harm, non-incineration treatment technologies are a growing and developing field. Most medical waste is incinerated, a practice that is short-lived because of environmental considerations. The burning of solid and regulated medical waste generated by health care creates many problems.   What are the types of incinerator? The following are types of incinerators:     ROTARY KILN.     FLUIDIZED BED.     LIQUID INJECTION.     MULTIPLE HEARTH.     CATALYTIC COMBUSTION.     WASTE-GAS FLARE.     DIRECT-FLAME.   Which biomedical waste is incinerated? The 4 categories that medical waste falls under are General, Infectious, Hazardous and Radioactive. Biomedical waste is incinerated in either a hospital  incinerator or through industry standard biomedical waste incinerators.       Nanjing Clover

Google快讯 – medical waste

medical waste 实时更新 ⋅ 2021年9月11日 新闻 Indian Railway Recruitment 2021: Government job vacancies for more than 400 posts in … DNA India Mechanic Medical equipment for hospitals and occupational health